- Input voltage (V)
|
Single-phase 220Vac±10%, 50/60Hz or Single-phase 230Vac, 50/60Hz
Tri-phase 380Vac±10%, 50/60Hz or tri-phase 415Vac, 50/60Hz |
- Output voltage
|
0 ~ 600V (continuously adjustable) |
- Output current
|
0 ~ 50000A (continuously adjustable) |
- Output power
|
0 ~ 800KW |
- Control mode
|
PWM |
- Working mode
|
CC voltage-limit / CV current-limit working modes, manual switchable. |
- CV (constant voltage) accuracy
|
≤±1% |
- CC (constant current) accuracy
|
≤±1% |
- Overall efficiency
|
≥90% |
- Power factor
|
≥0.95 |
- Output display
|
LED digital display |
- Regulation range
|
Voltage/current 0 ~ 100% rated value continuously adjustable |
- Cooling method
|
Forced air cooling or water cooling or oil cooling (as per requirements) |
- Protection function
|
Input over voltage, lack voltage, lack phase, over current protections.
Output short, over heat and IGBT self-lock protections |
- Control mode
|
10-turn potentiometer & remote control box (3m long)
LCD touch screen (optional) |
- Insulation resistance
|
Input – output: ≥20MΩ
Input – shell: ≥20MΩ
Output – shell: ≥20MΩ |
- Insulation strength
|
Input – output: 1500Vac, 10mA, 1min.
Input – shell: 1500Vac, 10mA, 1min.
Output – shell: 1500Vac, 10mA, 1min. |
- Over heat protection threshold value
|
65~85℃ (overall) |
- Working mode
|
Withstand long-term continuously working at full load |
- Indication
|
Working: LED (GREEN), Over heat: LED (YELLOW), Fault: LED (RED) |
- Display mode
|
Output voltage, current display
Working, over heat & fault indication |
- Environment
|
Temperature: -0℃ ~ 40℃
Humidity: 15%~90%
Height: ≤1500m
No flammable, corrosive object, no vibration & explosion |
- Remote control (optional)
|
0~10V, 4~20mA analog signal control.
RS232 or RS485 communication port. |
- Size
|
Depends on output |
- Other optional functions
|
Pulsing output (a s per requirements)
Polarity reverse function (as per requirements)
Output timing (as per requirements) |